| General Situation |
Simulator classification |
AAA |
| IEC Standards |
IEC 60904-9 |
| Method of measurement |
Light Intensity calibration by standard solar cell |
| Test functions |
Ioc, Voc, Im,Pm,FF,Rs,Eff,I-V vurve |
| Optical Properties |
Irradiation area |
16cm*16cm |
| Light direction |
Up |
| Spectrum classification |
AM 1.5 Class A |
| Non-uniformity of radiance |
±2% |
| LTI |
±1% |
| STI |
±0.5% |
| Light Pulse width |
5ms |
| Lamp lifetime |
300000 times |
| Range of light intensity |
700~1200W/m 2 , adjustable |
| Electrical Properties |
Current ranges |
0~0.75A/1.5A/3A/6A/12A |
| Voltage ranges |
0~16V |
| Non-repeatability of test power |
±0.5% |
| Voltage/current resolution |
1/214*range |
| Test connection model |
Precise motor, import elastic probe |
| Acquisition system |
Voltage, current, light intensity can be taken simultaneously |
| Adjust method of electronic load |
Adjust method of electronic load |
| Reverse voltage range |
0~15V |
| Reverse control method |
Keyboard or button |
| Software system |
Test time |
<2s |
| Time for data acquisition |
3ms~4ms |
| Software update |
Free |
| Grading setting |
According to Pmax, Id |
| Temperature correction |
Automatic |
| Database |
Yes (Data, Image) |
| Total system size |
400mm(L)*510(W)*860mm(H) |
| Phase, voltage, frequency |
220VAC±10%, 5A, 50Hz |
| Application environment |
25ºC±10ºC: relative moisture ≤80% |